APP NAME: SBL2EXA Factory Application ========================================================================================= App Version: 1.06 NNDK Version: 2.6.0 Compile Date: 2012.10.04 Notes: Standard Release - Automatically restore serial hardware flow control if enabled when a connection is accepted on a listening port - Fixed serial hardware flow control performance ----------------------------------------------------------------------------------------- App Version: 1.05 NNDK Version: 2.6.0 T020 Compile Date: 2012.06.18 Notes: Modified Standard Release - Extended the time to wait for DHCP address before outputting the failure message via debug port from 6 to 10 seconds; a message indicating that DHCP acquisition failed would sometimes appear despite being successful ----------------------------------------------------------------------------------------- App Version: 1.04 NNDK Version: 2.5.3 T012 Compile Date: 2011.10.24 Notes: Modified Standard Release - Added the "Learn UDP reply port" option ----------------------------------------------------------------------------------------- App Version: 1.03 NNDK Version: 2.5.3 T002 Compile Date: 2011.04.27 Notes: Modified Standard Release - Fixed issue with ARP over UDP when an attempted outgoing connection is made before the target device is connected to the network ----------------------------------------------------------------------------------------- App Version: 1.02 NNDK Version: 2.5.0 Compile Date: 2010.12.02 Notes: Modified Standard Release - Added options to select 5 or 6 stop bits when configuring the serial settings through the AT command set - Fixed the reversed issue with the outgoing connection idle time-out and retry time-out values for both ports - Extended the time to wait for DHCP address before outputting the failure message via debug port from 5 to 6 seconds; a message indicating that DHCP acquisition failed would sometimes appear despite being successful - Remove the RTS/CTS hardware flow control option in the serial configuration web page for serial port 1 ----------------------------------------------------------------------------------------- App Version: 1.01 NNDK Version: 2.4 RC3 Compile Date: 2010.09.10 Notes: Standard Release - Increased incoming TCP idle timeout default value from 30 to 60 seconds - Decreased outgoing TCP retry timeout default value from 60 to 10 seconds - Changed custom baud rate default value from 9600 to 0 bps (115,200 bps selectable by default) - Outgoing TCP connect name default is “(Enter IP address)” instead of blank - UDP mode settings are removed from custom packetization category into its own category - Outgoing TCP connect port default value is now “1000” and “1001” for port 0 and 1, respectively - Pins 3 and 4 in GPIO settings are now shown to indicate that they are connected to a level shifter and go in one direction only ----------------------------------------------------------------------------------------- App Version: 1.00 NNDK Version: 2.4 RC3 Compile Date: 2010.09.02 Notes: Initial Beta Release -----------------------------------------------------------------------------------------